Shift summary for Day November 11, 1996 [Gollwitzer, McTaggart] Finished taking the point 1MeV above the chi_2 peak. Total integrated luminosity after HV fix is ~1pb^-1. Decelerated to chi_2 peak; start run 762. DAQ runs smoothly after increasing size of gold buffer which appears to have stopped the DFM_E_OUT_OF_RANGE errors which caused the filter to crash previously. Otherwise a smooth data taking shift (Pedlar was informed of problem with luminosity PC data acquisition stream; this does not affect the UNIX based data acquisition of the luminosity data). Note to other shifters: Please put ORIGINAL copies of run and rate sheets in the log-book; put the copies in the binder.