04/22/00 Evening Shift Summary: (Log Book: #7, p.105-108) On shift: MN,MG Data Type: chi0 (Ecm=3416 MeV) Beam current at start: 38 mA . Beam current at end: 32.5 mA . Typical Luminosity: (3.0-3.5) x 10^31 cm^-2s^-1 Run: 5530 (281.7 nb-1) inherited 5531 (278.1nb-1) 5532 in progress Comments: At 17:15 MCR called to say He2 from Tevatron became contaminated (probably due to some work done earlier in the day). The pump that gets the helium from the Tevatron to the VLPCs tripped a while later due to these impurities. The VLPC temperature increased and at 18:20 the fibers were turned off. The problem was fixed and the VLPCs were cooled down and the fibers were turned on again at 20:00... There were a number of hangs unaccompanied by DAQ messages. These were traced back to DYCs 3 and 5, which were found to have there "Data In" lights on. The nozzle was unclogged twice. Other than that, pretty smooth.... Good Night, Matteo, Matt ata In" lights on. The nozzle was unclogged twice. Other than that, pretty smooth.... Good Night, Matteo, Matt