On Shift: DC, PR Log Book #8, pp 204 & 205 Data type: 1P1 (3525.8 MeV) Run Summary: Run 7021 (inherited) 324.6 nb^-1 Run 7022 Beam current at start: 12.6 mA Beam dumped at 22:00 with 9.06 mA Luminosity: 2.5 -> 1.9 x 10^31 cm^-2 s^-1 Typical sigma Ecm: 230 KeV/c Energy stable about the requested value Comments: 1 nozzle unclogging 3 DAQ hangs End of stack script performed Summary of data taking for this stack: Run End Lum. # GM out triggers ---- ------ ----- ----------------- 7018 STOP 335.1 48778500 Have a good night, 7019 STOP 326.4 46771404 David and Paolo 7020 STOP 311.6 45238647 7021 STOP 331.0 46942379 7022 ABORT 367.8 52044514 Note (mainly for Keith): the DAQ STOP was issued for run 7022, as it is recorded in the dish database... we don't understand why the above list reports an ABORT. Have a good night, David and Paolo